Image Problem: Too Light.

Trouble Shooting

StepCauseSolutionParts
1TR(Transfer roller) of the drum unit does not rotate smoothly.Clean TR (see blow).
2Drum unit defective.Replace the drum unit.Drum (015-0289-21)
3Develop unit defective.Replace the develop unit.Develop unit (015-0204-21)
4HVPS (High-Voltage Power Supply) defective.Replace HVPS.HVPS (005-3141-9-SP)
5Main board defective.Replace the main board MBA890.Main board:
AM7630i (004-3479A-9-SP)
AM7640i (004-3479B-9-SP)
AM5630i (004-3479C-9-SP)
AM5640i (004-3479D-9-SP)

Clean TR (transfer roller)

Loosen 3 fixing screws to remove the metal frame. Check the Transfer roller position and confirm whether there are any foreign object.