Icon

Trouble Shooting
Step | Cause | Solution | Parts |
1 | USB cable defective. | Replace the USB cable. | USB cable (104-6133-9-SP) |
2 | Main broad defective. | Replace the main board MBA872. | Main board AD8150 (004-3407-9-SP) AD8150N (004-3407A-9-SP) AD8150NP (004-3407B-9-SP) |