Error Code 201617: Fuser Error.

  • Post author:
  • Post category:

Trouble Shooting StepCauseSolutionParts1The thermostat is shutting off due to overheat.Replace the thermostat.Thermostat (008-0361-9-SP)2Fuser temperature sensor defective.Relace thermistor temperature sensor. (for A4 or A3 lamp).Fuser temperature sensor (008-0347-9-SP).3Lamp of fuser defective.Replace…

Continue ReadingError Code 201617: Fuser Error.

Error Code 201616: Fuser Error.

  • Post author:
  • Post category:

Trouble Shooting StepCauseSolutionParts1Fuser temperature sensor defect.Replace thermistor temperature sensor.Fuser temperature sensor (008-0347-9-SP).2Main board defect.Relace main board MBA890.Main board:AM7630i (004-3479A-9-SP)AM7640i (004-3479B-9-SP)AM5630i (004-3479C-9-SP)AM5640i (004-3479D-9-SP)